<noframes id="v1vxt"><form id="v1vxt"><span id="v1vxt"><track id="v1vxt"></track></span></form>

    <address id="v1vxt"></address> <em id="v1vxt"></em>

    <noframes id="v1vxt">
    <noframes id="v1vxt"><form id="v1vxt"></form><noframes id="v1vxt"><form id="v1vxt"></form>

        <noframes id="v1vxt">
          <noframes id="v1vxt"><form id="v1vxt"></form>
          歡迎來到泉州萬達不銹鋼制品廠官網! 收藏我們 | 網站地圖
        1. 行業新聞

        2. 您現在的位置:首頁 > 新聞中心 > 行業新聞
          不銹鋼消防水箱的行業標準與水質化驗
          作者:  來源:http://www.xysxc.com  更新時間:2021-06-07 15:45:10  點擊次數:
          不銹鋼消防水箱的行業標準與水質化驗
           
           不銹鋼消防水箱設置在建筑物最高部位,依靠重力自流向消火栓或自動噴水滅火系統供水,用來撲救初期火災(十分鐘)的供水設施,采用臨時高壓給水系統的建筑物應設消防水箱。
           Stainless steel water tank is arranged in a building highest position, rely on gravity to the fire hydrant or the sprinkler water supply system, used for initial fire fighting ( ten minutes ) of water supply facilities, using temporary high pressure water supply system in building should be set fire water tank.
           將增壓水泵出水管作為消防水箱的出水
           pressurized water pump outlet pipe, as fire water tank water
           消防技術規范規定,最不利點消火栓靜水壓力不應低于0.07Mpa,最不利點噴頭的工作壓力不應低于0.05Mpa。在實際設計中,消防水箱往往需要設置增壓水泵來滿足壓力要求。有些設計人員將增壓水泵出水管作為消防水箱的出水管,這是非常錯誤的做法。這是因為,設置增壓水泵的主要目的是在火災初期消防水泵啟動前,滿足消火栓和自動噴水滅火系統的水壓要求,其出水量對消火栓給水系統不應大于5L/s,對自動噴水滅火系統不應大于1L/s,顯然大大小于規范要求的室內消防用水量,不能滿足撲救初期火災水量的要求。所以,在屋頂設置的增壓水泵,應在增壓水泵出水管一側設旁通管,出水流量不應小于撲救初期火災需要的用水量。
           Fire technical specification, the most unfavorable point fire hydrant hydrostatic pressure should not be less than 0.07Mpa, the most disadvantageous sprinkler working pressure shall not be less than 0.05Mpa. In the actual design, fire water tank is often required to meet the requirements of pressure booster pump. Some designers will be a booster water pump outlet pipe as fire water tank outlet pipe, this is very wrong. This is because, setting water booster pump is aimed primarily at the initial stage of a fire fire pump priming, meet the fire hydrant and sprinkler system water pressure, the water on the fire hydrant water supply system should not be greater than 5L / s, on the sprinkler system should not be greater than 1L / s, was considerably less than the standard indoor fire water use, can not meet the requirement of the fire at initial stage. So, on the roof of a booster water pump set, should be in the booster water pump outlet pipe is arranged on one side of the bypass pipe, the water flow should not be less than the initial fire fighting needs water.
           生活水箱清洗及水質化驗
           1 生活水箱清洗完成之前和之后,均必需采取水樣,送檢水樣必需密封,送檢水樣的密封標簽上必需注明采樣人姓名、采樣日期和時間、監護人姓名和監護日期及時間,并在24小時以內送檢。
           2 生活水箱清洗作業不得嚴重影響正常使用。
           3 生活水箱清洗方案必需得到審核批準后方可實施。
           4 清洗生活水箱用的化學藥劑、清洗工具必需符合相關衛生和健康要求,并不得對環境發生二次污染。
           5 生活水箱清洗工作人員必需持有有效健康體檢合格證。
           6 生活水箱清洗方案必需要有應急預案和應急供水預案。
           7 清洗生活水箱的工作人員必需佩戴平安衛生的防護裝備。 
          不銹鋼消防水箱
           
          本文鏈接:http://www.manawatelephone.com//content/?309.html
          上一篇:方形不銹鋼消防水箱功能說明與特點
          下一篇:不銹鋼消防水箱的容積計算

          相關文章

          不銹鋼消防水箱檢測報告合格證-2020-06-16
          不銹鋼消防水箱材質國家規定-2020-05-28
          不銹鋼消防水箱箱泵一體化-2020-05-21
          不銹鋼消防水箱故障處理-2020-05-08
          不銹鋼消防水箱安裝規范-2020-04-27
          不銹鋼消防水箱能用幾年-2020-04-21
          不銹鋼消防水箱設置的規范-2020-04-14
          不銹鋼消防水箱厚度國標-2020-04-07
          組合裝配式焊接不銹鋼水箱的特點-2022-04-26
          不銹鋼肋板水箱的檢驗規則-2022-04-18
          內置式水箱自潔消毒器臭氧原理和應用范圍-2022-04-13
          不銹鋼消防水箱廠家推出新技術突破“潛規則”-2022-04-08
          電熱恒溫水箱與水箱的區別-2022-03-29
          不銹鋼消防水箱廠家儲水量設計要求-2022-03-22
          不銹鋼消防水箱廠家產品分類-2022-03-15
          极速快三